hidden
Hình bìa
Loại tài liệu:
Article
Tác giả:
Fonseca-Santos, B.
Đề mục:
Arabian Journal of Chemistry
Nhà xuất bản:
Elsevier Ltd.
Ngày xuất bản:
November 2017
Định dạng:
pdf
Nguồn gốc:
Arabian Journal of Chemistry, Volume 10, Issue 7, November 2017, Pages 1029-1037
Ngôn ngữ:
eng
Lượt xem:
0
Lượt tải:
0

Nội dung

A simple, rapid, and sensitive analytical procedure has been developed and validated for the in vitro measurement of curcumin in samples from mucosae retention studies. Curcumin was analyzed by HPLC using a C18 column with UV detection at 425 nm. The mobile phase was acetonitrile and water (50:50 v/v) acidified with 2% acetic acid at a flow rate of 1.2 mL min−1. The curve range was linear for the receptor solution concentration range 0.5–75 μg mL−1. The specificity showed no interference with the biological matrix and excipients of the acceptor media. Intra and inter-day accuracy, and precision values were lower than 5% and were not statically different (P < 0.05). Recoveries ranged from 99.7% to 108%. The limits of detection and quantitation were 11.61 and 500 ng mL−1, respectively. The method is adequate to assay curcumin from esophageal porcine samples, enabling the determination of penetration profiles for in situ gelling curcumin-loaded liquid crystals by in vitro studies, and fulfilled the requirements for reliability and feasibility for application to the quantitative analysis of curcumin in porcine esophageal mucosae.

Tập tin đính kèm

Loại file Tên file Dung lượng Chi tiết
201707AJC1029-1037.pdf 1273753 Kb XemTải